RFID and Vision Camera for Traceability System

SSCN Number : SSCN-0011
Project Number : FASKL-1905-400
Solution : Traceability Vision + RFID
Industries : Graphite Electrodes

Problem Statement

- Operator manual log in the product ID after the laser mark.

- The start inspection time and data and end time must able to log in to the server for traceability purpose.

Solutions

Vision Camera:

- Using the 12 Mp Smart Camera to detect the OCR code and send the read data to the PLC for logging.


RFID:

- All the electrode are fixed with the RFID tag from the input conveyor.

- The first reader read the ID and start test time when the electrode load to test station.

- The second reader read the data after the test process.

- Both readers send data to PLC for test result confirmation.